A blue pool with a yellow sign, a hand holding a litmus paper applied to pH scale

pH

What is pH and What Does It Measure?

pH is a measure of the hydrogen ion activity in a solution. Pure water that contains an equal balance of positive hydrogen ions (H+) and negative hydroxide ions (OH-) has a neutral pH.

Featured pH/ORP Analyzers and Testing Products

Portable pH Meters

Portable pH Meter

Simple and affordable pH measurement for home, school, and hobbyist use. Hach's pH testers deliver quick and easy measurements with accurate and reliable results. We also offer pH buffer solutions for our testers.

View Products

Benchtop pH Meters

HQD

Accurate and precise pH measurement for laboratory and industrial applications. Hach's benchtop pH meters offer advanced features and user-friendly interfaces.

View Products

pH / ORP Sensors and Probes

DPD

Select the right sensor or probe for precise pH/ORP measurement. Explore and shop our wide range of solutions that suit your application now.

View Products

Controllers and Transmitters

LXV

Ensure consistent pH control with Hach's reliable suite of controllers and transmitters. Choose from our range of automated solutions for various applications.

View Products

pH Testers

pH tester

Simple and affordable pH measurement for home, school, and hobbyist use. Hach's pH testers deliver quick and easy measurements with accurate and reliable results.

View Product

pH Test Strips

pH Test Strip

Take the guesswork out of pH testing with Hach's pH test strips. Our high-quality strips provide quick and dependable readings for a variety of applications.

View Products

Which Processes Require pH Monitoring?

pH of drinking water is measured at multiple stages in a drinking water plant. Normal pH range for tap water is 6.5-8.5 throughout both treatment process and distribution. Drinking water pH level must be monitored to minimize corrosion, contamination and adverse effects on taste, odor, color and appearance.


View Products

A drinking water treatment plant monitors pH in several stages of water purification.

Methods for Monitoring pH

Potentiometric Method

This method uses a pH sensing system (including a pH meter, a pH sensing electrode and a pH reference electrode) to take an electrochemical measurement to precisely determine where the tested fluid falls on the pH scale.

Advantages

This is the most accurate method for pH measurement. Portable, lab or process/online options are available for this method. This method can be EPA approved for monitoring pH.

Disadvantages

This method requires proper handling, care and maintenance of the pH probe and involves higher instrument costs.

Our online technology course provides more information on the importance of monitoring and measuring pH.

Visual Method

An indicator solution changes color when added to the solution being tested. That color change is then visually compared against a color chart to determine pH.

Advantages

This method is simple, inexpensive and portable.

Disadvantages

Solutions being tested with this method must be free of color and have no turbidity. Solutions being tested with this method must not have a secondary reaction with the indicator solution. No online or process options exist for this method. This method does not produce exact measurements.

Liquid Indicator Dyes

Liquid dyes are added directly to the solution to produce a color change that indicates changing pH.

Wide Range pH Indicator Solution, 1 L
2329353
Price: Contact Us
Wide Range pH Indicator Solution, 500 mL
2329649
Price: Contact Us
Phenol Red Indicator Solution, 500 mL
21149
Price: Contact Us
TKN Indicator Solution, 50 mL SCDB
2251926
Price: Contact Us
Phenolphthalein Indicator Solution, 100 mL
2330242
Price: Contact Us
Methyl Purple Indicator Solution, 500 mL
2193449
Price: Contact Us

Paper Strips/Test Strips

Dye-infused paper strips are dipped into a solution and then change color to indicate corresponding pH. This method is not affected by color or turbidity in a sample.

MEL/P-A Safe Drinking Water Lab
2569600
Price: Contact Us
pH Test Strip, 7.5-14 pH units, 100 tests
2751000
Price: Contact Us
Stream Survey Test Kit
2712000
Price: Contact Us

Photometric Method

Like the visual method used in test strips and color wheels, an indicator solution is used to create a color change in the solution being tested. However, with this method the color change is not assessed by the human eye, it is measured by a photometer (colorimeter or spectrophotometer) to produce a more precise pH reading.

Advantages

This method is portable, removes the subjectivity of the human eye and does not require complex pH meter calibration.

Disadvantages

Solutions being tested with this method must be colorless. No online/process options exist for this method and there are costs associated with instruments. This method is not an EPA-approved method for monitoring pH.

Frequently Asked Questions

View Products and Services

Your selection

  • pH

Market Class

Parameter

Product Type

Product Sub-Type

Application

Topic

Topic Detail

Method/Technology

Method Number

Location

Industry

Loading

Have Questions? We Have Answers!

Contact us for tech support, service, sales, or to get a quote.