BOD Trak II Manometric BOD apparatus with accessories

BOD Trak II Manometric BOD apparatus with accessories

Product Number: 2952400

Price: Contact Us
Talk to an Expert

Hazardous Materials

Hazardous shipping. Items with this mark may be considered hazardous under some shipping conditions. If necessary, we will change your selected shipping method to accommodate these items.
  • Corrosive
  • Caution

Simplified BOD analysis.

Manometric BOD(n) laboratory measurement station, control unit and stirrer with pressure sensors for 6 bottles.
BOD measurement programmes for 5, 7, 10 days, OECD biodegradation test for 30 days.
Measuring range 0-700 mg/L O2, variable.
Incl. 6 rubber sleeve stoppers, 6 492-mL brown glass bottles, grease, 6 magnetic stirrers, funnel, 1 pkg LiOH Powder Pillows, 1 pkg nutrient Powder Pillows.

Applications:

  • Boiler Water
  • Industrial Wastewater
  • Municipal Water
  • Pre-Treatment
  • Steam Cycle

Benefits

Decrease total test time

The Hach BODTrak II Apparatus is easy to set up and allows for quick sample preparation for BOD (Biochemical Oxygen Demand) analysis. Simply pour a measured sample of wastewater and nutrient buffer into each of six BODTrak II bottles. Connect the bottles to the instrument's pressure sensors, select a measurement range, and incubate. User calibration of the instrument is not necessary.

Faster than Dilution Method

Constant stirring in the bottles supplies additional oxygen to the sample and provides bacteria with greater exposure to food. This results in more rapid respiration and consumption of oxygen.

BOD results that are easy to monitor

The BODTrak II Apparatus has a large graphic display that continuously updates results. View the results at any time during the test. The instrument plots a curve of BOD over time. To review the data in detail, simply move a cursor along the curve to display results for any stored data point.

Standalone operation

The apparatus automatically ends the test and stores teh results after the chosen test length of five, seven, or ten days. This eliminates the need to be present when the test is complete.

DO probes and titrations are eliminated

The BODTrak II Apparatus measures BOD using the respirometric method. Each sample bottle is connected to a pressure sensor in a closed system. As bacteria consume oxygen in the sample, the pressure in the bottle headspace drops. This pressure change correlates directly to BOD. By measuring pressure changes instead of dissolved oxygen levels, the need for probes and titrations is eliminated.

Improved procedures with expanded options