Product Number: 9494500
The IO9001 Module adds versatility to the AS950 automatic sampler. The IO9001 is available for simple applications that only require 1 high voltage relay. For a broader range of inputs and outputs, see the IO9004.
The IO9000 Module allows the use of digital and analog inputs and outputs with the AS950 sampler. With the IO9000 module, the AS950 provides more input and output options than any other Hach sampler before it. For added versatility the IO9000 is available in two versions; IO9001 is available for simple applications that only require 1 high voltage relay while the IO9004 is fully loaded. See specifications for more detail.
The digital outputs can be used to indicate an alarm or an event. Analog 0/4-20 mA outputs can be used to send information to a SCADA system for parameters such as level, velocity, flow and pH. Examples of alarms and events include: sensor outside of limits (flow related, water quality related, internal temperature or ambient temperature), program started, program completed, sample being taken, bottle full (single bottle), pump running forward, pump running in reverse, pump error, distributor error, power failure, or main battery low.
Analogue 0/4-20mA inputs can be used to trigger a sample from water quality sensors or flow meters and can be logged.
Like the digital outputs, these relay outputs are used to indicate alarms or events. The difference is that relays can be used for switching AC mains line voltage to control higher power functions. Examples for use are for a warning light or sound signal, switching a diversion valve or gate or a control signal to another machine.
*when applicable
Phase Out
Items with this label are at the end of their life cycle and may become obsolete in the future.
Obsolete
Items with this label are obsolete and unavailable through eCommerce.
If applicable, please view Replacement Product above or contact Hach Customer Service for further assistance.