104732: Sodium Arsenite Solution, 5.0 g/L, 100 mL |
Solution |
0.02 - 2.00 mg/L Cl₂ |
10059 DPD Rapid Liquid Method, Pour-Thru Cell™ DPD Rapid Liquid Method for Free Chlorine
|
|
|
Contact Hach
|
Solution |
0.0 - 10.0 mg/L Cl2 |
10069 DR900 UHR
|
|
|
Solution |
0.1 - 10.0 mg/L Cl2 |
10069 DPD, HR Powder Pillows
|
|
|
Solution |
0.09 - 5.00 mg/L Cl2 |
10102 DPD Test 'N Tube
|
|
|
Solution |
0 - 4.00 mg/L |
10245 DR800 DPD Powder Pillows DPD Method Powder Pillows
|
Y
|
|
Solution |
0.02 - 2.00 mg/L Cl2 |
8021 DPD Powder Pillows or AccuVac®
|
Y
|
View
|
199901: Phenylarsine Oxide (PAO) Digital Titrator Cartridge, 0.00564 N |
Digital Titrator |
0 - 1,000 µg/L Cl₂ |
10024
|
Y
|
View
|
Contact Hach
|
2440400: Reagent set, chlorine, DPD free & total chlorine, 25 mL sample |
|
0 - 3.5 mg/L |
DPD Color Disc
|
|
View
|
Contact Hach
|
2155332: Buffer, Phosphate Type, pH 7, for Amperometric Chlorine, 100 mL MDB |
Solution |
0.1 - 5 mg/L Cl₂ |
AT1000 Amperometric Titration Automatic Titrator Method
|
|
|
Contact Hach
|
Solution |
0.5 mg/L and above Cl₂ |
8334 Amperometric Buret Titration Method
|
Y
|
|
Solution |
0 - 1,000 µg/L Cl₂ |
10024
|
Y
|
View
|
199953: Phenylarsine Oxide (PAO) Standard Solution, 0.00564 N, 1 L |
Solution |
0.1 - 5 mg/L Cl₂ |
AT1000 Amperometric Titration Automatic Titrator Method
|
|
|
Contact Hach
|
Solution |
0.5 mg/L and above Cl₂ |
8334 Amperometric Buret Titration Method
|
Y
|
|
Solution |
0 - 10 mg/L Cl₂ |
8335 Amperometric Titration
|
|
|
2333353: Iodine Standard Solution, 0.0282 N, 1 L |
Solution |
0.1 - 5 mg/L Cl₂ |
AT1000 Amperometric Titration Automatic Titrator Method
|
|
|
Contact Hach
|
1490932: Acetate Buffer Solution, pH 4.0, 100 mL |
Solution |
0.1 - 5 mg/L Cl₂ |
AT1000 Amperometric Titration Automatic Titrator Method
|
|
|
Contact Hach
|
199917: Phenylarsine Oxide (PAO) Standard Solution, 0.00564 N, 3.78 L |
Solution |
0 - 1,000 µg/L Cl₂ |
10024
|
Y
|
View
|
Contact Hach
|
2142001: Phenylarsine Oxide (PAO) Digital Titrator Cartridge, 0.0451 N |
Digital Titrator |
0 - 10 mg/L Cl₂ |
8335 Amperometric Titration
|
|
|
Contact Hach
|
1426820: Chlorine Standard Solution, 50-75 mg/L as Cl2, pk/20 - 2 mL PourRite« Ampules |
Solution |
0.04 - 4.50 mg/L Cl₂ |
10241 Powder Pillows Indophenol
|
|
|
Contact Hach
|
2700349: Phenylarsine Oxide (PAO) Titrant, 0.00564N, 500 mL |
Solution |
0.5 mg/L and above Cl₂ |
8334 Amperometric Buret Titration Method
|
Y
|
|
Contact Hach
|
104532: Sodium Hydroxide Standard Solution, 1.000 N, 100 mL MDB |
Solution |
0.02 - 2.00 mg/L Cl2 |
8021 DPD Powder Pillows or AccuVac®
|
Y
|
View
|
Contact Hach
|
199849: Phenylarsine Oxide (PAO) Standard Solution, 0.000564 N, 500 mL |
Solution |
0.1 - 5 mg/L Cl₂ |
AT1000 Amperometric Titration Automatic Titrator Method
|
|
|
Contact Hach
|
2635300: SpecCheck Secondary Gel Standards Set, DPD Chlorine - LR |
|
0.02 - 2.00 mg/L Cl2 |
8021 DPD Powder Pillows or AccuVac®
|
Y
|
View
|
Contact Hach
|
199849: Phenylarsine Oxide (PAO) Standard Solution, 0.000564 N, 500 mL |
Solution |
0 - 10 mg/L Cl₂ |
8335 Amperometric Titration
|
|
|
Contact Hach
|
34332: Potassium Iodide Solution, 30 g/L, 100 mL MDB |
Solution |
0.1 - 10.0 mg/L Cl2 |
10069 DPD, HR Powder Pillows
|
|
|
Contact Hach
|
2314011: Free chlorine indicator solution for chlorine analyser CL17/CL17sc (473 mL) |
Solution |
0.02 - 2.00 mg/L Cl₂ |
10059 DPD Rapid Liquid Method, Pour-Thru Cell™ DPD Rapid Liquid Method for Free Chlorine
|
|
|
Contact Hach
|
34332: Potassium Iodide Solution, 30 g/L, 100 mL MDB |
Solution |
0.02 - 2.00 mg/L Cl₂ |
10059 DPD Rapid Liquid Method, Pour-Thru Cell™ DPD Rapid Liquid Method for Free Chlorine
|
|
|
Contact Hach
|
2556900: Free Chlorine Reagent Set for chlorine analyser CL17/CL17sc |
Solution |
0.02 - 2.00 mg/L Cl₂ |
10059 DPD Rapid Liquid Method, Pour-Thru Cell™ DPD Rapid Liquid Method for Free Chlorine
|
|
|
Contact Hach
|
34332: Potassium Iodide Solution, 30 g/L, 100 mL MDB |
Solution |
0.05 - 4.00 mg/L Cl2 |
10245 DPD, MR Powder Pillows
|
|
|
Contact Hach
|