TU5300sc Low Range Laser Turbidimeter with Flow Sensor, Automatic Cleaning, RFID, and System Check, EPA Version with SC200 Controller, 24 VDC, 1 Channel
Product #: 2979455K

OBSOLETE ITEM

Groundbreaking 360° x 90° Detection Technology

The TU5 Series employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.

Matching lab and online results

For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection Technology in both instruments.

Everything about turbidity – faster

The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.

No surprises

Prognosys monitors your TU5 Series online instrument, proactively alerting you to maintenance needs before your measurement becomes questionable. And a Hach Service Agreement protects your investment and helps ensure that you stay in compliance and on budget.

Specifications

Accuracy: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
±10% of reading from 40 - 1000 NTU based on Formazin primary standard
Cable Length: 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories
Calibration Method: For Formazin and Stablcal:
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range

Custom calibration for up to 6-point calibrations
Certifications: CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian ACMA Marking
Channels: 1
Communication: System Check & RFID
Controller: 1 Channel, 24 VDC
Controller Options: Yes
Dimensions (H x W x D): 249 mm x 268 mm x 190 mm
Fitting type: Sample quick connector: ¼-in. for ¼-in. tubing
Instrument: With Flow Sensor and Automatic Cleaning Module
Light source: Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Lower Limit of Detection (LOD): 0.002 NTU
Material: ASA S 777K / RAL7000, TPE RESIN Elastocon STK40,
Thermoplastic Elastomer TPS-SEBS
Model: TU5300sc
Mounting Configurations: Wall Mount
Operating Humidity: Relative humidity: 5 - 95% at different temperatures, non-condensing
Operating temperature range: 0 - 50 °C
Options: Process Head, Flow Sensor, & Automatic Cleaning Module
Power requirements (Voltage): 24 V DC
Range: EPA:
0 - 700 NTU / FNU / TE/F / FTU
0 - 175 EBC
Regulatory: EPA
Repeatability: TU5300 sc: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
TU5400 sc: Better than 1% of reading or ±0.0006 NTU on Formazin at 25 °C (77 °F), whichever is greater
Response Time: T90 <30 секунди при 100 mL/min
Sample Pressure: 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F)
Sample Temperature: 2 to 60 °C (35 to 140 °F)
Signal Average Time: 30 to 90 seconds
Storage conditions: -40 to 60 °C (-40 to 140 °F)
Stray Light: <10 mNTU
System Check: Yes
Units: NTU, FNU, TE/F, FTU, EBC
Verification: Liquid: Stablcal, Formazin (0.1 to 40 NTU)
Dry: Glass Rod at <0.1 NTU
Weight: 2.7 kg (5.0 kg with all accessories)