Release Notes

Check this page for a full list of software releases, upgrades, and technical specifications for Claros, the Water Intelligence System from Hach.

Claros Software Releases

 


 

Release Notes: Claros 2020.3   OCTOBER 27th, 2020

Claros Platform: What's New

  • New parameters have been added to the Claros library:
    • Hydrogen Chloride
    • Valve Position
    • Nitrogen Dosing Rate
    • Phosphoric Acid Liquid Feed Rate
    • Sodium Hypochlorite Liquid Feed Rate
    • Reductant Liquid Feed Rate
    • Acid Liquid Feed Rate
    • Caustic Liquid Feed Rate
    • Coagulant Liquid Feed Rate
    • RTC Manifold Pressure Setpoint, Computed
    • RTC Valve Position Setpoint, Computed
    • RTC Acid Liquid Feed Rate, Computed
    • Reductant Dosing Rate, Computed
    • RTC Sodium Hypochlorite Liquid Feed Rate, Computed
    • RTC Nitrogen/COD Dosing Rate, Computed
    • RTC Phosphorous/COD Dose, Computed
    • RTC Phosphorous Liquid Feed Rate, Computed
    • RTC Carbon Liquid Feed Rate, Computed
    • RTC Internal recirculation flow, Computed
    • RTC Caustic Liquid Feed Rate, Computed
    • RTC Coagulant Liquid Feed Rate, Computed
    • RTC Nitrogen Liquid Feed Rate, Computed

Instrument Management - What's New

  • Mobile Sensor Management is now available on the sc200 via the Claros Connector, which allows customers to receive the benefits of MSM with existing Claros enabled sensors. Please click here for more information about what sensors are compatible with MSM.
  • Customers can now receive in-app or email notifications when measurement values exceed user-selected limits.* This feature allows users to take the appropriate action when sensor measurements exceed or fall below a set threshold.
    *This feature is a beta release and will be available only to a limited number of users. Please contact clarosfeedback@hach.com for more information.
  • Measurements from the 1720E Turbidimeter are now available to view in MSM.

Data Management - What's New

  • We are developing new data management features and are looking for customers to beta test the new functionality. If you are interested, please contact clarosfeedback@hach.com

* North America only: *

Process Management - What's New

  • Additional RTC modules now available in Claros MSM. These modules are: SND, C/N/P, DN. When connected, these RTC modules appear as connected devices through the Claros MSM user interface, providing secure remote access to RTC data and settings on any device. This functionality compliments the Claros MSM access already available for our other RTC modules: RTC-P, N, N/DN, SRT, ST and SD

Release Notes: Claros 2020.2   AUGUST 4th, 2020

Claros Platform: 2020.2

  • Bug fixes and stability improvements
  • Beta testing opportunities for both Data and Process Management customers. If interested, please contact clarosfeedback@hach.com

Instrument Management

  • New sensors added:
    • 3400sc - Contacting Conductivity sensor series
    • 3700sc - Inductive Conductivity sensor series
    • 8362sc - Pure Water pH analyzer and other pH combination sensors
    • 9184sc - Chlorine analyzer
    • 9185sc - Ozone analyzer
    • 9187sc - Chlorine Dioxide analyzer
    • SS7sc - Surface Scatter 7 sc
    • Ultraturb sc Turbidimeter
  • New Wi Fi connectivity mode for sc4200 controller: WPA/WPA2 Enterprise

Data Management

  • New parameters added to the Claros library
  • We are seeking customers to beta test our new visualization tools (e.g. gauge widget, waterfall graph and multi-axis graph). To learn more, click here.

* North America only: *

Process Management

  • RTC Platform now on Windows 10 IoT operating system
    • All RTC modules will now ship on Windows 10
    • All supporting Industrial PCs offered now include upgrades for additional memory and a faster CPU required for running RTC on Windows 10
    • No change in software or equipment part numbers
    • TeamViewer software used for remote monitoring must be upgraded to the latest version, TV15
    • Existing RTC installations can be upgraded to Windows 10 with the purchase of a new Industrial PC and a software upgrade fee
  • New options available for Sludge Retention Time (SRT) process management through Hach’s RTC-SRT Module
    • Based on overall SRT (not just Aerobic SRT)
    • SRT management for non-nitrifying plants
  • New options available for DAF process management through Hach’s RTC-DAF Module
    • Parts per million (PPM) -based dosing control
    • Control of three chemicals: coagulant, anionic flocculant and cationic flocculant
    • Extended pH control both pre- and post- DAF
    • Process flow style visualization

Release Notes: Claros 2020.1   MAY 12th, 2020

Claros Platform: 2020.1

  • Bug fixes and stability improvements
  • Beta testing opportunities for both Data and Process Management customers. If interested, please contact clarosfeedback@hach.com

Data Management

  • New parameters added to the Claros library
  • We are seeking customers to beta test our new visualization tools (e.g. gauge widget, waterfall graph and multi-axis graph). To learn more, click here.

* North America only: *

Claros Web

Claros Collect for iOS and Android

Estimated release date: May 12th, 2020

iOS Version 2.4.4

  • Bug fixes and stability improvements

Android Version 2.4.7

  • Bug fixes and stability improvements

Release Notes: Claros 2019.4   FEBRUARY 11th, 2020

Claros Platform: 2019.4

  • New supported languages: Czech and Slovakian
  • Inclusion of the Graphs Widget on the dashboard
  • Graphs will show data every 5 minutes (previously every minute)

Instrument Management

  • New sensors added:
    • CL10 sc Amperometric Chlorine Analyzer
  • Prognosys Measurement and Service Indicators implemented
    for digital communication (Modbus TCP) to SCADA
  • New dashboard Instrument Alert widget added

Data Management

  • New parameters added to the Claros library
  • New dashboard gauge widget added ( Beta Testing)
  • New dashboard waterfall graph widget added ( Beta Testing)
  • New dashboard multi-axis graph widget added ( Beta Testing)

* North America only: *

Process Management

RTC Platform changes:

  • RTC-DO (DO Control: closed-loop zone DO control with aeration intensity as output)
  • RTC-MOV (Most Open Valve DO Control: closed-loop zone DO control with air valve position, pressure on manifold or overall pressure as output)

Claros Web

Claros Collect for iOS and Android

Estimated release date: February 11, 2020

iOS Version 2.4.3

  • New supported languages: Czech and Slovakian

Android Version 2.4.4

  • New supported languages: Czech and Slovakian

Release Notes: Claros 2019.3   OCTOBER 15th, 2019

Claros Platform: 2019.3

  • New supported language: Croatian
  • New dashboard that includes a Plant Map, Links, and Weather
  • Bug fixes and stability improvements

Instrument Management

  • MSM & RTC integration: RTC modules are available in the MSM application

Data Management

* North America only: *

Process Management

RTC Platform changes

  • Parameter change history
  • Event log history
  • Login and change password procedure according to Danaher Safety Security Assessment
  • UI separation between Operator and Service area
  • New Service UI enabling simplified loop checks
  • Improved RTC SCADA
    • Simplified parameter group selection
    • Adjustable auto refresh mode
    • Time span selection

RTC to Claros integration

  • For P, N/DN, N, SRT, ST, SD- RTC
    • RTC data available on Claros UI (from 19.2)
    • RTC settings can be changed through Claros UI

RTC Modules

  • RTC DAF (Dissolved Air Flotation: Load based control for coagulant and flocculant)

Claros Web

Claros Collect for iOS and Android

iOS Version 2.4.3

  • No updates

Android Version 2.4.4

  • No updates

Release Notes: Claros 2019.2   JULY 23rd, 2019

Claros Platform: 2019.2

  • New supported language: Turkish
  • Bug fixes and stability improvements

Instrument Management

  • 4G/Verizon modem for SC4200c and SC1500 Controllers
  • 4G/GSM (all EU carriers, AT&T and T-Mobile) for SC1500 Controller
  • Revision of Prognosys Predictive Diagnostic Software messages

Data Management

* North America only: *

Claros Web

Claros Collect for iOS and Android

Estimated release date: July 23, 2019

iOS Version 2.4.3

  • App now available in Slovakia, Croatia and Czech Republic – English only
  • New Supported Languages: Turkish and Greek

Android Version 2.4.4

  • App now available in Slovakia, Croatia and Czech Republic – English only
  • New Supported Languages: Turkish and Greek

Release Notes: Claros 2019.1   APRIL 30th, 2019

Claros Platform: 2019.1

  • Various bug fixes

Instrument Management

  • Diagnostic features, allowing to diagnose the Internet connectivity of the SC4200c controller series
  • Bug fixes including some data display issues

Data Management

  • New location/site configuration tool for Drinking Water Distribution Systems that enables users to copy and paste location/site names and addresses from a spreadsheet
  • Bug fixes including some data display issues

* North America only: *

Process Management

  • New CLAROS Process Management modules for:
    • Oxidation Ditches with Simultaneous Nitrification Denitrification (RTC-SND)
    • Denitrification (RTC-DN)
    • Dissolved Air Flotation (RTC-DAF)
    • Nutrient Dosing (RTC-C/N/P)
  • New feature on RTC-ST:
    • Adjustment of specific dosing rate depending on feed TSS concentration
  • SIEMENS IPC Hardware as alternative to BECKHOFF IP Hardware available

Claros Web

Claros Collect for iOS and Android

Estimated release date: April 30th, 2019

iOS Version 2.4.2

  • Addition of DR300 parameters
  • Updated translation strings
  • Bug fixes

Android Version 2.4.3

  • Addition of DR300 parameters
  • Updated translation strings
  • Bug fixes

Release Notes: Claros 2018.4   JANUARY 29th, 2019

Claros Platform: 2018.4

  • New supported languages: Romanian, Bulgarian, Slovenian, and Hungarian

Instrument Management

  • Added PHOSPHAX sc LR analyzer
  • Added TSS sc sensor
  • Added WiFi connectivity for SC4200c controller series
  • Added SIM cards to every cellular version of SC4200c and SC1500 modems – customers can now purchase annual data plans from Hach (MSM_DATAPLAN) if they wish to use this card
  • Improved 4-20 mA Input card (Channel name is made available in the UI) for sc1500 controller series
  • Various bug fixes

Data Management

  • New ability to add text variables. Users are not limited to a pre-determined list.
  • New ability to relocate data from the 4-20mA input card data from Instrument Management to Data Management.

Claros Web

Claros Collect for iOS and Android

iOS Version 2.4.0

  • New ability to transfer measurements from a DR300 colorimeter to Claros Collect for iOS
  • New ability to view a list of DR300 devices that are connected or previously were connected to Collect.
  • Bug fixes
  • New ability to add text variables. Users are not limited to a pre-determined list.
  • New supported languages Romanian, Bulgarian, Slovenian, and Hungarian

Android Version 2.4.0

  • Performance improvement when loading bench sheets, for customers with a large number of process/locations
  • New ability to transfer measurements from a DR300 colorimeter to Claros Collect for Android.
  • New ability to view a list of DR300 devices that are connected or previously were connected to Collect.
  • Bug fixes New ability to add text variables. Users are not limited to a pre-determined list.
  • New supported languages Romanian, Bulgarian, Slovenian, and Hungarian

Release Notes: Claros 2018.3    OCTOBER 30, 2018

 

Claros Platform: 2018.3

  • New supported language: Portuguese

Instrument Management

  • Added 2-channel versions of the AMTAX sc and PHOSPHAX sc analyzers
  • Streamlined email notifications
  • Enhanced firmware update procedure
  • Resolved issues related to MODBUS TCP in combination with cellular internet communication
  • Resolved issues related to Workflows
  • 3G/4G data plans now available for MSM customers

Data Management

  • Improved plant set up design and added functionality for easy parameter search
  • Added User defined text selection in the Custom Observations menu. Allows a user to define the name and list of values to be selected that can then be added as a Location Parameter. See HSO article for a how to.
  • Added ability for users to hide standard bench sheets and have a streamlined view for data entry
  • Added ability to download data to Excel from the spreadsheet view

Claros Collect for iOS and Android (Estimated release date October 9th, 2018)

 

iOS Version 2.3.0

  • Ability to display and select custom non-numeric parameters
  • Ability to hide standard bench sheets and have a streamlined view for data entry
  • Bug fixes including data download issues
  • New supported language Portuguese

Android Version 2.3.0

  • Ability to display and select custom non-numeric parameters
  • Ability to hide standard bench sheets and have a streamlined view for data entry
  • Bug fixes including data download issues

 

 

Release Notes: Claros 2018.2    AUGUST 7, 2018

 

Claros Platform: 2018.2

  • New Privacy Notice to comply with General Data Protections Regulation in Europe

Instrument Management

  • Added feature to increase efficiency of maintenance work by batching workflows
  • Added MODBUS/TCP digital communication protocol for SC1500 controllers,
  • Added capability to receive and process analog mA input signals to SC1500 controller
  • Improved the verification workflows for A/N-ISE sc, AMTAX sc and PHOSPHAX sc (sensor menus are no longer blocked while waiting for lab results)
  • Decreased the time it takes to load the measurement values of all sensors in the system

Data Management

  • Bug fixes and improved translated content

Claros Collect for iOS and Android

 

iOS Version 2.2.1

  • Fixed rare issue where the app could freeze

Android Version 2.2.1

  • Small layout fixes

 

 

Release Notes: Claros 2018.1    MAY 14, 2018

 

Claros Platform: 2018.1

  • New landing page will allow the user to access application specific content.
  • New user interface and navigation elements.
  • Added ability to integrate Instrument Management and Data Management products in one easy to navigate application.
  • Added application performance improvements.
  • Added supported languages.

Instrument Management

  • Added ability to view and trend measurement values from Claros-enabled sensors (MSM data) in spreadsheets and graphs.
  • Added ability to complete or cancel ongoing Maintenance Workflows by any user with administrator privileges.
  • Added sludge profile graphing for Sonatax sc sensor.
  • Added ability to freely configure timers for specific maintenance tasks.
  • Added ability for SC4200c controller to share internet access through one single modem.
  • Added ability for administrators to remove user.
  • Added supported languages: Swedish.
  • Improved overall communication robustness
  • Improved Maintenance Notification handling (notification will disappear once the maintenance has been done, independent from whether through the Workflow or the Sensor Menu).
  • Improved Calibration/verification workflows (Workflow can’t start without a DR3900 or DR6000 provisioned in the tenant).
  • Improved display of Sonatax sc limits during configuration (showing an appropriate amount of digits after the decimal point)
  • Fixed issue related to not displaying Phosphate HR measurement value
  • Fixed issue related to MSM grab samples workflows for the Amtax sc and Phosphax sc analyzers (all available parameters (NH4, NH4-N, PO4, PO4-P, P2O5) are supported)
  • Fixed performance issues related to Danish language setting

Data Management

  • New navigation allows the user to access content specific to their daily scope of work.
  • Added ability to up load measurement values in Excel format.
  • Added ability to access Help articles.
  • Added ability to convert units of measure.
  • Measurement values from Claros enabled sensors (MSM data) can now be viewed in spreadsheets and graphs.
  • Improved functionality during plant set up.
  • Units list only shows logical selections for the Parameter when setting up parameters (Water Temperature only shows °C, °F in the unit’s selection list).
  • Plant setup now only shows current plant making navigation easier.
  • Added supported languages: Danish, Dutch, French, German, Italian, Polish, Spanish, and Swedish.

Claros Collect for iOS and Android

 

iOS Version 2.2.0

  • Added gesture, pull to refresh data.
  • New icons added.
  • New plant sort option.
  • Added functionality for multilingual support.
  • Improved multi-user support.
  • Improved sort order for Bench sheets.
  • Bug fixes including synch issues and lay out.

Android Version 2.2.0

  • Added gesture, pull to refresh data.
  • New icons added.
  • New plant sort option.
  • Added functionality for multilingual support.
  • Improved multi-user support.
  • Improved sort order for Bench sheets.
  • Bug fixes including synch issues and layout.